Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(1): e13845, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36411733

RESUMO

Realizing the potential of user-developed automation software interacting with a treatment planning system (TPS) requires rigorous testing to ensure patient safety and data integrity. We developed an automated test platform to allow comparison of the treatment planning database before and after the execution of a write-enabled script interacting with a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA) using the vendor-provided Eclipse Scripting Application Programming Interface (ESAPI). The C#-application known as Write-Enable Script Testing Engine (WESTE) serializes the treatment planning objects (Patient, Structure Set, PlanSetup) accessible through ESAPI, and then compares the serialization acquired before and after the execution of the script being tested, documenting identified differences to highlight the changes made to the treatment planning data. The first two uses of WESTE demonstrated that the testing platform could acquire and analyze the data quickly (<4 s per test case) and facilitate the clinical implementation of write-enabled scripts.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Software , Planejamento de Assistência ao Paciente
2.
Radiother Oncol ; 158: 246-252, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33711411

RESUMO

BACKGROUND: Ultracentral lung cancers arise near the proximal bronchial tree (PBT), trachea, or esophagus, and have been associated with worse outcomes and increased toxicity after radiotherapy. We sought to associate dosimetric and anatomic factors with oncologic outcomes and toxicities. METHODS: One-hundred ten patients treated with ablative, curative-intent radiotherapy for ultracentral, node-negative, non-small cell lung cancer were included. Dosimetric and geometric data obtained using custom software that calculated volumes of target structures and organs-at-risk and measured the shortest vector length between these volumes were associated with outcomes and toxicity. RESULTS: Common dose/fractionation schemes included 50 Gy in 5 fractions (57%), 60 Gy in 8 fractions (15%), and 48 Gy in 4 fractions (13%). Overall survival at 1, 2, and 5 years was 78%, 57%, and 32%, respectively. Factors significantly associated with death included endobronchial tumor, gross tumor volume (GTV) or planning target volume (PTV) contacting PBT, shorter distance from GTV to PBT or esophagus, volume of PBT receiving prescription dose, higher pericardium max dose, lung V20Gy, and mean lung dose. Local progression at 1, 2, and 5 years was 4%, 16%, and 21%. Factors associated with local progression were lower GTV minimum dose and higher GTV/PTV volume ratio. Acute and late grade 2 + toxicity was seen in 18% and 27%, respectively. Four patients (4%) had fatal toxicity. CONCLUSIONS: Lower GTV minimum dose and smaller volumetric PTV expansions may increase risk of local progression, and should be balanced against normal tissue doses including pericardium maximum dose, lung V20Gy, and mean lung dose.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Fracionamento da Dose de Radiação , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
3.
J Appl Clin Med Phys ; 17(1): 421-427, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894353

RESUMO

In this Technical Note, we describe an in-house video goggles feedback system assembled using several commercially available products. This goggle video feed-back system is currently being used at University of Louisville and Mayo Clinic for both CT simulation and linac treatment delivery. The setup details, including specific recommendations, are provided, along with an alternative option for using the video goggles system.


Assuntos
Retroalimentação Sensorial , Movimento (Física) , Neoplasias/radioterapia , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...